Features:

1. Embedded with high performance VOX detector, delicate image output with 1024*768 OLED display

2. 7 Reticle types available for different scheme or target, 4 presets for different product type

3. Optical magnification, digital zoom and PIP to catch the target clearer & closer

4. Optimized button operations, friendly user interface

5. Notes: The Picatinny Rail is not include

Specifications:

Resolution

384x288

Pixel size

17u

Objective lens

35mm

Field of view

10.5x8

Magnification

2.4-9.6x

NETD

≤50

Frame rate

50Hz

Display

1024×768 OLED

Eye relief

48mm

Diopter adjustment

-6D~+4D

Reticle

Multiple Patterns Color Options

Battery

CR123×4

Battery life

10hrs

IP rating

IP67

Net Weight

750g

Dimensions

230×55×50mm

Detection Rang

1200m

Mount

Picatinny

Package Includes:

1xBlack Thermal Imaging Scope

1x4PCS CR123 Battery

1xUser Manual

W2588A (13).jpg

Function and operation instruction:

1、Battery installation

  1.png         

  2.png

  Unscrew the battery compartment cover counterclockwise according to the icon on the battery compartment cover; According to the icon prompt in the cabin cover, load four CR123 batteries into the battery compartment with the negative pole facing down and the positive pole facing up as shown in the figure above, and tighten the battery compartment cover clockwise.

2、Startup & Shutdown

        3.png

  Long press the power button for 3 seconds when the machine is shut down, and the gun aims start up.

 

     4.png

  Long press the power button for 3 seconds at startup, and the gun is shut down.

3. Diopter adjustment                                                                                                                                 

  After starting up, adjust the eyepiece by turning the eyepiece adjustment ring according to the personal vision and keep the picture clear and visible.                 

4. Focus adjustment

  According to the target position, by rotating the adjustment ring of the objective lens , do the focus operation.

  Short press the main menu button to enter the main menu. The menu interface is as shown below.5.png 

  Under the main menu, up, down, left and right buttons respectively control the four icon functions of "up, down, left and right" on the menu interface, as follows:

4.1 electronic amplification

  In the main menu mode, short press the up key to realize the loop zooming display of image 1x-2x-4x.

4.2 brightness adjustment

  In the main menu mode, press the button to control the brightness switch, and realize the four-level circular display of screen brightness.

4.3 image mode

  In the main menu mode, short press the left button to control the switching of image mode to achieve the display of black heat and white heat cycle.

4.4 correction mode

  In the main menu mode, press the right button to control the calibration, and press the shutter to adjust; Long press background correction.

5. Division display function operation

  Under the main menu function, continue to press the main menu key to switch out the secondary menu. The secondary menu is mainly divided menu, and the control screen shows the function of division. The interface of the secondary menu is shown in the figure below:6.png 

  Under the secondary menu, the four buttons of up, down, left and right also correspond to the four icon functions of "up, down, left and right" on the menu interface respectively. The details are as follows:

5.1 color changes

  In the secondary menu mode, press the up key to control the color switch, and achieve the black - white cycle display.

5.2 differentiation style changes

  In the secondary menu mode, press the button to control the split style switch, and realize the display of four styles of split cycle.

5.3 divide the blanking and ranging function

  In the secondary menu mode, short press the left button to control the display switch, and the display/display + ranging/ranging + range elimination cycle appears.

  The distance measuring function can be realized by pressing the left button to display the distance measuring + distance measuring, and the distance measuring is displayed in the lower left corner of the screen as shown in the figure: 

123.png

  The horizontal coordinate 1 in the figure indicates the height of the 180cm object displayed on the screen at 100m.

5.4 division position adjustment

  In the secondary menu mode, right click to enter the division adjustment interface, as shown below.

7.png 

  Under the division adjustment interface, the size icon in the corresponding screen realizes the up, down, left and right adjustment of the division position by the four keys of up, down, left and right.